中华皮肤科杂志 ›› 1989, Vol. 22 ›› Issue (5): 314-316.

• 论著 • 上一篇    下一篇

五种斑贴试验材料比较

颜艳, 刘景忠, 李安生   

  1. 中国医学科学院皮肤病研究所
  • 收稿日期:1988-04-18 修回日期:1988-10-04 出版日期:1989-10-15 发布日期:1989-10-15

Compatative study of five different materials used in patch test

YAN Yan, LIU Jing-Zhong   

  1. Institute of Dermatology, Chinese Academy of Medical Sciences, Nanjing
  • Received:1988-04-18 Revised:1988-10-04 Online:1989-10-15 Published:1989-10-15

摘要: 本文对5种不同的斑贴试验材料进行了对比研究,结果我们自制的内径13mm,深2mm的小室在去除斑贴物后24,48,72小时的阳性率及敏感性均高于其它各组,而其余组间无显著性差别.

Abstract: This paper reports the comparative study of five different materials used in patch test. The positive rates and sensitivity of the chamber made by ourself were higher than that of other groups at 24, 48, 72 hours. No significant differences in reaction were observed in other groups.